Predicted spent fuel quanatities in Finland

1 January 2000


Predicted accumulated fuel quantities at Olkiluoto (OL) and Loviisa (LO) units [3]
OL1 OL2 OL3 LO1 LO2
Design operating life (years) 60 60 60 50 50
Number of fuel assemblies 7224 7288 3728 3993 4380
Average burnup of all assemblies (MWd/kgU) 38.0 38.6 45.5 37.0 38.1
In tons of uranium (tU) 1270 1263 1980 492 526
Number of canisters 1210 932 698



Privacy Policy
We have updated our privacy policy. In the latest update it explains what cookies are and how we use them on our site. To learn more about cookies and their benefits, please view our privacy policy. Please be aware that parts of this site will not function correctly if you disable cookies. By continuing to use this site, you consent to our use of cookies in accordance with our privacy policy unless you have disabled them.